Rated capacity (Emax)
|
kg
|
3, 5, 7, 10, 15, 20, 30,
35, 50, 75
|
|
Sensitivity
|
mV/V
|
2.00
|
|
Sensitivity tolerance
|
± mV/V
|
0.20
|
|
Zero balance
|
± mV/V
|
0.10
|
|
Creep over 30min.
|
± %
|
0.025
|
0.017
|
0.017
|
0.0125
|
|
Temperature effect on zero
|
± %/10 °C
|
0.060
|
0.040
|
0.014
|
0.014
|
|
Temperature effect on output
|
± %/10 °C
|
0.014
|
0.010
|
0.010
|
0.0075
|
|
Eccentric loading error
|
±%/cm
|
0.0057
|
0.0042
|
|
Maximum platform size
|
cm
|
35x35
|
|
Nominal temperature range
|
°C
|
-10 to +45
|
|
Service temperature range
|
°C
|
-30 to +70
|
|
Limit load
|
% of R.C.
|
150
|
|
Break load
|
% of R.C.
|
300
|
|
Nominal excitation
|
V
|
10
|
|
Max. excitation
|
V
|
15
|
|
Input impedance
|
Ohm
|
415 ± 15
|
|
Output
impedance
|
Ohm
|
350 ± 3
|
|
Insulation
resistance
|
MOhm
|
>2000
|
|
Compensation
circuit type
|
|
Balanced Bridge
|
|
Cable
length
|
Meter
|
0.5
|
|
Cable
type
|
|
4x28 AWG, Braid Shielded, Black PVC
Jacket
|
|
Color
code
|
|
+exc -green,
+sig-red, -exc-black, -sig-
white
|
|
Construction
|
|
Aluminum
|
|
Protection
class to IEC529
|
|
IP 66
|
|
|
|
|
|
|